products

EN 598 ISO 2531 Ductile Iron Pipe Other End Spigot DI Pipe Anti Corrosion

Basic Information
Place of Origin: CHINA
Certification: ISO2531,WRAS,SGS,ISO9001,ISO14001
Model Number: DN80-DN2600mm
Minimum Order Quantity: 1TONS
Packaging Details: WOODEN BOX/PALLET,SHIPPED BY SEA(CONTAINER OR BULK VESSEL),BY AIR ECT.
Delivery Time: 30DAYS
Payment Terms: L/C, T/T
Contact Now
Detail Information
Joint: Flange Casting Method: Weld
Length: As Customer's Requirement Shape: Round
Diameter: DN80-1400mm Hydro Test: 100%
High Light:

mechanical joint ductile iron pipe

,

puddle flange pipe


Product Description

EN 598 ISO 2531 Ductile Iron Pipe Other End Spigot DI Pipe Anti Corrosion

 

Flanged Ductile Iron Pipe:

Flanged ductile iron pipe with a range of DN80 to DN 2600.belongs to Ductile iron pipeline systems, including pipes, fittings, accessories and joints, consist of various materials.When used for conveying water intended for human consumption, the materials in contact with the water shall meet the relevant requirements of the national standards or regulations in the country of use with respect to effect on water quality.The lengths of flanged pipes shall be as given. Other lengths are available by agreement between the manufacturer and the purchaser.

 

Specifications:

 

Tensile properties

 

 

Minimum tensile strength, Rm

MPa

Minimum elongation after fracture, A

 

%

DN 80 to DN 2000 DN 80 to DN 1000 DN 1100 to DN 2000
Pipes centrifugally cast 420 10 7
Pipes not centrifugally cast, fittings and accessories 420 5 5

By agreement between manufacturer and purchaser, the 0,2 % proof stress (Rp0,2) may be measured. It shall be not less than:

¾ 270 MPa when A ³ 12 % for DN 80 to DN 1000 or A ³10 % for DN > 1000;

¾ 300 MPa in other cases.

 

      Compressive strength of the cement mortar lining

 

The compressive strength shall be the arithmetic mean of six compressive strength tests performed on three prism samples after 28 days of curing.

The compressive strength shall be determined by a performance-test in accordance with EN 196-1, except that:

  • sand, cement and the water used for the prism samples are identical with those used for the mortar before application of the lining;
  • sand/cement ratio used for the prism samples is equal to that used for the mortar before application of the lining;
  • water/cement ratio used for the prism samples is equal to that of the lining immediately after application to the pipe wall;
  • test samples are prepared using either an impact table (in accordance with EN 196-1) or a vibrating table (2 min at 63 Hz) when the water/cement ratio is below 0,35.

 

Packing: in wooden box or pallet, or in bulk

Shipment: in bulk or container

 

Usage:

Ductile iron pipeline systems, including pipes, fittings, accessories and joints, consist of various materials.When used for conveying water intended for human consumption, the materials in contact with the water shall meet the relevant requirements of the national standards or regulations in the country of use with respect to effect on water quality. When used under the conditions for which they are designed, in permanent or in temporary contact with water intended for human consumption, ductile iron pipes, fittings and their joints shall not have detrimental effects on the properties of that water for its intended use.

 

Our advantages:

 

There are lots of qualified managers and technicians, and a well-trained team of after-sales service, which provides all services of manufacture, package, transportation and installation. We are looking forward to cooperating with friends from abroad and home creating a brighter future.

 

Contact Details
sales01

Phone Number : 86-371-53378091